Branched Convolutional Neural Networks for Receiver Channel Recovery in High-Frame-Rate Sparse-Array Ultrasound Imaging

8Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

For high-frame-rate ultrasound imaging, it remains challenging to implement on compact systems as a sparse imaging configuration with limited array channels. One key issue is that the resulting image quality is known to be mediocre not only because unfocused plane-wave excitations are used but also because grating lobes would emerge in sparse-array configurations. In this article, we present the design and use of a new channel recovery framework to infer full-array plane-wave channel datasets for periodically sparse arrays that operate with as few as one-quarter of the full-array aperture. This framework is based on a branched encoder-decoder convolutional neural network (CNN) architecture, which was trained using full-array plane-wave channel data collected from human carotid arteries (59 864 training acquisitions; 5-MHz imaging frequency; 20-MHz sampling rate; plane-wave steering angles between -15° and 15° in 1° increments). Three branched encoder-decoder CNNs were separately trained to recover missing channels after differing degrees of channelwise downsampling (2, 3, and 4 times). The framework's performance was tested on full-array and downsampled plane-wave channel data acquired from an in vitro point target, human carotid arteries, and human brachioradialis muscle. Results show that when inferred full-array plane-wave channel data were used for beamforming, spatial aliasing artifacts in the B-mode images were suppressed for all degrees of channel downsampling. In addition, the image contrast was enhanced compared with B-mode images obtained from beamforming with downsampled channel data. When the recovery framework was implemented on an RTX-2080 GPU, the three investigated degrees of downsampling all achieved the same inference time of 4 ms. Overall, the proposed framework shows promise in enhancing the quality of high-frame-rate ultrasound images generated using a sparse-array imaging setup.

Cite

CITATION STYLE

APA

Pitman, W. M. K., Xiao, D., Yiu, B. Y. S., Chee, A. J. Y., & Yu, A. C. H. (2024). Branched Convolutional Neural Networks for Receiver Channel Recovery in High-Frame-Rate Sparse-Array Ultrasound Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 71(5), 558–571. https://doi.org/10.1109/TUFFC.2024.3383660

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free