Abstract
Resolution measurements were made using 14.1 MeV neutrons from a high-yield, portable DT neutron generator and a neutron camera based on a scintillation screen viewed by a digital camera. Resolution measurements were made using a custom-built, plastic, USAF-1951 resolution chart, of dimensions 125 × 98 × 25.4 mm3, and by calculating the modulation transfer function from the edge-spread function from edges of plastic and steel objects. A portable neutron generator with a yield of 3 × 109 n/s (DT) and a spot size of 1.5 mm was used to irradiate the object with neutrons for 10 min. The neutron camera, based on a6LiF/ZnS:Cu-doped polypropylene scintillation screen and digital camera was placed at a distance of 140 cm, and produced an image with a spatial resolution of 0.35 cycles per millimeter.
Author supplied keywords
Cite
CITATION STYLE
Williams, D. L., Brown, C. M., Tong, D., Sulyman, A., & Gary, C. K. (2020). A Fast Neutron Radiography System Using a High Yield Portable DT Neutron Source. Journal of Imaging, 6(12). https://doi.org/10.3390/jimaging6120128