Bleeding in patients with continuous-flow left ventricular assist devices: acquired von Willebrand disease or antithrombotics?

4Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: To evaluate the competing pro-haemorrhagic contribution of acquired von Willebrand (vW) disease and antithrombotic therapy in patients implanted with continuous-flow left ventricular assist devices (LVADs). METHODS: We compared the extent of vW factor (vWf) degradation [vWf antigen (vWf:Ag)] and a decrease of functional activity of large vWf multimers [vWf collagen binding (vWf:CB)] in LVAD patients who did and did not suffer from bleeding. Data were measured pre-implant, at short-term (t1: <3 months) and long-term (t2: >12 months) follow-up. The occurrence of primary bleeding events, as well as bleeding recurrence, was correlated with patient-specific vWf profile and antithrombotic regimen. Indeed, patients were discharged on warfarin (international normalized ratio: 2-2.5) and aspirin, with the latter withhold after a first bleeding episode. RESULTS: Fifty-three patients were enrolled. The median follow-up was 324 (226-468) days. We recorded 25 primary bleeding events (47% of patients). All primary events occurred in patients on warfarin and aspirin. Both vWf:Ag and vWf:CB decreased significantly post-implant (P = 0.0003 and P < 0.0001), and patients showing pathological vWf:CB/vWf:Ag ratio (<0.7) increased progressively over the time of support (pre-implant = 26%, t1 = 58%, t2 = 74%; P < 0.0001). Of note, activity of large vWf multimers of bleeders was significantly lower at t2 with respect to non-bleeders (vWf:CB: 61 (36-115) vs 100 (68-121), P = 0.04; vWf:CB/vWf:Ag ratio: 0.36 (0.26-0.61) vs 0.58 (0.33-0.96), P = 0.04). Despite these marked differences in the vWf profile, following aspirin discontinuation only 3 patients had bleeding recurrence. CONCLUSIONS: Aspirin contributes significantly to haemorrhagic events in the background of acquired vW disease; its discontinuation significantly reduces bleeding recurrence. Clinical trial registration: https://clinicaltrials.gov/ct2/show/NCT03255928; ClinicalTrials.gov Identifier: NCT03255928.

Cite

CITATION STYLE

APA

Consolo, F., Marasi, A., Della Valle, P., Bonora, M., Pieri, M., Scandroglio, A. M., … Pappalardo, F. (2022). Bleeding in patients with continuous-flow left ventricular assist devices: acquired von Willebrand disease or antithrombotics? European Journal of Cardio-Thoracic Surgery, 62(1). https://doi.org/10.1093/ejcts/ezab474

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free