Development of small-scale models to understand the impact of continuous downstream bioprocessing on integrated virus filtration

22Citations
Citations of this article
45Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

We designed small-scale virus filtration models to investigate the impact of the extended process times and dynamic product streams present in continuous manufacturing. Our data show that the Planova 20N and BioEX virus filters are capable of effectively removing bacteriophage PP7 (>4 log) when run continuously for up to 4 days. Additionally, both Planova 20N and BioEX filters were able to successfully process a mock elution peak of increased protein, salt, and bacteriophage concentrations with only an increase in filtration pressure observed during the higher protein concentration peak. These experiments demonstrated that small-scale viral clearance studies can be designed to model a continuous virus filtration step with specific process parameters.

Cite

CITATION STYLE

APA

Lute, S., Kozaili, J., Johnson, S., Kobayashi, K., & Strauss, D. (2020). Development of small-scale models to understand the impact of continuous downstream bioprocessing on integrated virus filtration. Biotechnology Progress, 36(3). https://doi.org/10.1002/btpr.2962