Abstract
Introduction We compared the efficacy and safety of human regular insulin (HRI) versus rapid-acting insulin (RAI) in a type 2 diabetes population already using the V-Go insulin delivery device. Research design and methods This was a 14-week, multicenter, randomized, open-label, parallel-group, phase IV, non-inferiority study. Patients ≥21years of age, with inadequately controlled type 2 diabetes who were currently using the V-Go insulin delivery system with RAI, with glycated hemoglobin (HbA1c) ≥6.5% (≥48 mmol/L) to ≤12.5% (≤108 mmol/L) were randomized 1:1 to RAI continuation or switch to HRI. The primary outcome was estimated treatment difference (ETD) in HbA1c least-squares mean change from baseline at 14 weeks (prespecified non-inferiority hypothesis with 95% CI upper limit <0.4%). Primary analysis was by per protocol (PP); safety analysis was by intention to treat. Results We randomized 136 patients to continued RAI treatment (n=67) or HRI (n=69); 113 patients were included in the PP analysis (RAI, n=54; HRI, n=59). Mean change in HbA1c from baseline to study end was -0.60±1.1% (95% CI -0.90 to -0.29); -6.6±12.0 mmol/mol (95% CI -9.8 to -3.2) with HRI treatment and -0.38±1.3% (95% CI -0.70 to -0.05); -4.2±14.2 mmol/mol (95% CI -7.7 to -0.5) with RAI treatment, with ETD of -0.22% (95% CI -0.67 to 0.22); -2.4 mmol/mol (95% CI -7.3 to 2.4), p=0.007, confirming non-inferiority of HRI to RAI. No between-group differences in changes in total daily insulin doses, number of hypoglycemic values (≤70 mg/dL (≤39 mmol/L) or body weight were observed. No severe hypoglycemic events were reported. Direct pharmacy cost savings (-US$265.85; 95% CI -US$288.60 to -US$243.11; p<0.0001) were observed with HRI treatment. Conclusions Individuals with type 2 diabetes requiring insulin can be treated with V-Go wearable insulin delivery device using HRI, safely and effectively, and potentially at a much lower cost compared with RAI, which can lead to improved access to insulin therapy for these individuals. Trial registration number NCT03495908.
Author supplied keywords
Cite
CITATION STYLE
Mora, P. F., Sutton, D. R., Gore, A., Baliga, B., Goldfaden, R. F., Nikkel, C., … Adams-Huet, B. (2020). Efficacy, safety and cost-effectiveness comparison between U-100 human regular insulin and rapid acting insulin when delivered by V-Go wearable insulin delivery device in type 2 diabetes. BMJ Open Diabetes Research and Care, 8(2). https://doi.org/10.1136/bmjdrc-2020-001832
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.