Abstract
Typical underground water storage facilities consist of reinforced concrete tanks and pipes. Although methods of their analysis are well developed, the use of these methods does not always give unambiguous results, as presented in the paper. An example of underground tank is considered in which cylindrical roof collapsed during construction under soil and excavator loads. The causes of failure are investigated with deterministic and stochastic models. In the first step nonlinear finite element analysis including soil-structure interaction was performed to examine overall level of the structural safety, which was found satisfactory thus not explaining the collapse. In the second step an analytical stochastic model was developed and analysed with emphasis to sensitivity. The last analysis explained the collapse as a complex of unfavourable states for considered variables and the failure was rec-ognised as a mixed construction-geotechnical-structural problem. The key role played backfill properties and its depth.
Cite
CITATION STYLE
Wróblewski, R., & Kozubal, J. (2019). Finite element and analytical stochastic models for assessment of underground reinforced concrete water storage facilities and results of their application. PLoS ONE, 14(1). https://doi.org/10.1371/journal.pone.0209916