Lumen-apposing metal stents for partial reversal of Roux-en-Y gastric bypass: a multicenter study

4Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background and Aims Roux-en-Y gastric bypass (RYGB) is an effective treatment of obesity; however, some patients may develop debilitating postoperative adverse events requiring surgical reversal, which can be technically challenging and highly morbid. Endoscopic ultrasound (EUS)–guided placement of a lumen-apposing metal stent (LAMS) offers a minimally invasive option that creates a gastrogastric fistula. Partial redirection of food into the native stomach results in improvement of nutritional status and may serve either as a bridge to surgery or as definitive therapy. Methods We report a prospective series of 16 patients with adverse events related to RYGB, from 4 tertiary care centers, who underwent EUS-guided LAMS placement and creation of a gastrogastric fistula due to either severe protein-calorie malnutrition, dumping syndrome, or postprandial hyperinsulinemic hypoglycemia. Results Technical and clinical success was achieved in 16 patients (100%) and 15 patients (93.75%), respectively. The median procedure duration was 30 minutes (range, 18-76 minutes). The mean body mass index increased significantly from the time of placement of a LAMS to a mean follow-up of 15.8 months (range, 3-62 months), 21.2 kg/m2 (range, 12.5-33.4 kg/m2) to 24.4 kg/m2 (range, 19.9-32.3 kg/m2) (mean difference: 3.19, P = .002). In addition, there was a statistically significant increase in mean hemoglobin and serum albumin at follow-up. Although there were no procedure-related adverse events, LAMS-related adverse events occurred in 4 patients and included pain, tissue ingrowth, and stent migration. Conclusions EUS-guided LAMS placement is a safe, efficacious, and minimally invasive strategy for partial reversal of RYGB either as a bridge to definitive surgical reversal or as destination therapy.

Cite

CITATION STYLE

APA

Kadkhodayan, K., Hussain, A., Chandan, S., Pathak, S. J., Almujarkesh, M. K., Abassi, A., … Irani, S. S. (2026). Lumen-apposing metal stents for partial reversal of Roux-en-Y gastric bypass: a multicenter study. Gastrointestinal Endoscopy, 103(5), 957–964. https://doi.org/10.1016/j.gie.2025.10.004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free