Long-Term Mortality After TAVI for Bicuspid vs. Tricuspid Aortic Stenosis: A Propensity-Matched Multicentre Cohort Study

4Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objectives: Patients with bicuspid aortic valve (BAV) stenosis were excluded from the pivotal trials of transcatheter aortic valve implantation (TAVI). We compared the in-hospital and long-term outcomes between patients undergoing TAVI for bicuspid and tricuspid aortic valve (TAV) stenosis. Methods: We performed a retrospective registry-based analysis on patients who underwent TAVI for BAV and TAV at five different centers between January 2009 and August 2017. The primary outcome was long-term all-cause mortality. Secondary outcomes were in-hospital mortality, procedural complications, and valve performance. Results: Of 1,451 consecutive patients who underwent TAVI, two propensity-matched cohorts consisting of 130 patients with BAV and 390 patients with TAV were analyzed. All-cause mortality was comparable in both groups up to 10 years following TAVI (HR 1.09, 95% CI: 0.77–1.51). Device success and in-hospital mortality were comparable between the groups (96 vs. 95%, p = 0.554 and 2.3 vs. 2.1%, p = 0.863, respectively). Incidence of procedural complications was similar in both groups, with a trend toward a higher rate of stroke in patients with BAV (5 vs. 2%, p = 0.078). Incidence of moderate or severe paravalvular leak (PVL) at discharge was comparable in both groups (2 vs. 2%, p = 0.846). Among patients with BAV, all-cause mortality was similar in self-expanding and balloon-expandable prostheses (HR 1.02, 95% CI: 0.52–1.99) and lower in new-generation devices compared to old-generation valves (HR 0.27, 95% CI 0.12–0.62). Conclusion: Patients who had undergone TAVI for BAV had comparable mortality to patients with TAV up to 10 years after the procedure. The device success, in-hospital mortality, procedural complications, and PVL rate were comparable between the groups. The high rate of neurological complications (5%) in patients with BAV warrants further investigation.

Cite

CITATION STYLE

APA

Gasecka, A., Walczewski, M., Witkowski, A., Dabrowski, M., Huczek, Z., Wilimski, R., … Kochman, J. (2022). Long-Term Mortality After TAVI for Bicuspid vs. Tricuspid Aortic Stenosis: A Propensity-Matched Multicentre Cohort Study. Frontiers in Cardiovascular Medicine, 9. https://doi.org/10.3389/fcvm.2022.894497

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free