Transient burnout under rapid flow reduction condition

5Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Burnout characteristics were experimentally studied using uniformly heated tube and annular test sections under rapid flow reduction conditions. Observations indicated that the onset of burnout under a flow reduction transient is caused by the dryout of a liquid film on the heated surface. The decrease in burnout mass velocity at the channel inlet with increasing flow reduction rate is attributed to the fact that the vapor flow rate continues to increase and sustain the liquid film flow after the inlet flow rate reaches the steady-state burnout flow rate. This is because the movement of the boiling boundary cannot keep up with the rapid reduction of inlet flow rate. A burnout model for the local condition could be applied to the burnout phenomena with the flow reduction under pressures of 0.5 - 3.9 MPa and flow reduction rates of 0.6 - 35%/s. Based on this model, a method to predict the burnout time under a flow reduction condition was presented. The calculated burnout times agreed well with experimental results obtained by some investigators. © 1987 Taylor & Francis Group, LLC.

Cite

CITATION STYLE

APA

Iwamura, T. (1987). Transient burnout under rapid flow reduction condition. Journal of Nuclear Science and Technology, 24(10), 811–820. https://doi.org/10.1080/18811248.1987.9735884