Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms

  • Wilson A
  • Quenneville P
  • Moon F
  • et al.
7Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Nail connections salvaged from the timber floor diaphragms of two ~100 year old unreinforced masonry buildings were pseudostatically tested to determine their hysteretic behavior. The research objective was to establish expected load-slip characteristics of nail connections in historic timber diaphragms to facilitate improved seismic assessment accuracy. A summary of the testing procedure, test results, and performance characterization is presented. Nail connections constructed from Kauri (Agathis australis) timber and wire-drawn nails in the 1890s were found to have an average yield strength of 1.0 kN and an average maximum strength 1.4 kN. Nail connections constructed in 1914 from Rimu (Dacrydium cupressinum) timber and wire-drawn nails were found to have an average yield strength of 0.8 kN and an average maximum strength of 1.0 kN. Both connection types exhibited an average ultimate displacement capacity of approximately 11.4 mm. ? 2014 American Society of Civil Engineers.

Cite

CITATION STYLE

APA

Wilson, A., Quenneville, P. J. H., Moon, F. L., & Ingham, J. M. (2014). Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms. Journal of Materials in Civil Engineering, 26(1), 202–205. https://doi.org/10.1061/(asce)mt.1943-5533.0000792

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free