Extracorporeal membrane oxygenation support for right ventricular failure after left ventricular assist device implantation

20Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: Right ventricular (RV) failure complicating left ventricular assist device implantation is associated with increased mortality. Despite a lack of supporting evidence, venoarterial extracorporeal membrane oxygenation (ECMO) support is increasingly being used as an alternative to traditional temporary RV support. We report our institutional experience with ECMO-facilitated RV support after left ventricular assist device implantation. METHODS: We retrospectively reviewed the concept of temporary ECMO support for perioperative RV failure in 32 consecutive left ventricular assist device (mean age 52 ± 14 years; male 84.4%; ischaemic cardiomyopathy 40.6%; INTERMACS Level I 71.8%; INTERMACS Level II 6.3%; INTERMACS Level III 12.5%; INTERMACS Level IV-VII 9.4%; HeartWare ventricular assist device 75%; HeartMate II: 25%) from May 2009 to April 2014. The study end points were RV recovery during ECMO support, mortality and causes of death. RESULTS: Twenty-nine (90.6%) patients were successfully weaned from ECMO support after RV recovery. Three (9.4%) patients expired during ECMO support. ECMO support improved RV function and haemodynamic parameters (central venous pressure 13mmHg vs 10 mmHg, P < 0.01; mean pulmonary artery pressure 28mmHg vs 21 mmHg, P < 0.01; cardiac output 5.1 l/min vs 5.9 l/min, P = 0.09) over a median period of 3 (range 1-15) days. Thirty-day and in-hospital mortality were 18.8% and 25%, respectively. One-year survival was 75%, causes of death were multiorgan dysfunction syndrome (50%), sepsis (25%), haemorrhagic stroke (12.5%) and ischaemic stroke (12.5%). Causes of death during ECMO support were ischaemic stroke, sepsis and multiorgan dysfunction syndrome. CONCLUSIONS: Temporary ECMO-facilitated RV support is associated with good long-term outcomes and high rates of RV recovery.

Cite

CITATION STYLE

APA

Riebandt, J., Haberl, T., Wiedemann, D., Moayedifar, R., Schloeglhofer, T., Mahr, S., … Zimpfer, D. (2018). Extracorporeal membrane oxygenation support for right ventricular failure after left ventricular assist device implantation. European Journal of Cardio-Thoracic Surgery, 53(3), 590–595. https://doi.org/10.1093/ejcts/ezx349

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free