Suspended timber ground floors: measured heat loss compared with models

4Citations
Citations of this article
52Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

There are approximately 6.6 million dwellings in the UK built before 1919, predominantly constructed with suspended timber ground floors whose thermal performance has not been extensively investigated. The results are presented from an in-situ heat-flow measuring campaign conducted at 27 locations on a suspended timber ground floor, and the estimated whole-floor U-value compared with modelled results. Findings highlight a significant variability in heat flow, with increased heat loss near the external perimeter. In-situ measured-point U-values ranged from 0.54 ± 0.09 Wm−2 K−1, when away from the external wall perimeter, to nearly four times as high (2.04 ± 0.21 Wm−2 K−1) when near the perimeter. The results highlight the fact that observing only a few measurements is likely to bias any attempts to derive a whole-floor U-value, which was estimated to be 1.04 ± 0.12 Wm−2 K−1 and nearly twice that derived from current models. This raises questions about the validity of using such models in housing stock models to inform retrofit decision-making and space-heating-reduction interventions. If this disparity between models and measurements exists in the wider stock, a reappraisal of the performance of suspended timber ground floors and heat-loss-reduction potential through this element will be required to support the UK’s carbon-emission-reduction targets.

Cite

CITATION STYLE

APA

Pelsmakers, S., Croxford, B., & Elwell, C. A. (2019). Suspended timber ground floors: measured heat loss compared with models. Building Research and Information, 47(2), 127–140. https://doi.org/10.1080/09613218.2017.1331315

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free