Long-term comparison between pulmonary homograft versus bioprosthesis for pulmonary valve replacement in tetralogy of fallot

28Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

Abstract

Background-—Tetralogy of Fallot repair results in late occurrence of pulmonary regurgitation, which requires pulmonary valve replacement in a large proportion of patients. Both homografts and bioprostheses are used for pulmonary valve replacement as uncertainty remains on which prosthesis should be considered superior. We performed a long-term imaging and clinical comparison between these 2 strategies. Methods and Results-—We compared echocardiographic and clinical follow-up data of 209 patients with previous tetralogy of Fallot repair who underwent pulmonary valve replacement with homograft (n=75) or bioprosthesis (n=134) between 1995 and 2018 at a tertiary hospital. The primary end point was the composite of pulmonary valve replacement reintervention and structural valve deterioration, defined as a transpulmonary pressure decrease ≥50 mm Hg or pulmonary regurgitation degree of ≥2. Mixed linear model and Cox regression model were used for comparisons. Echocardiographic follow-up duration was longer in the homograft group (8 [interquartile range, 4–12] versus 4 [interquartile range, 3–6] years; P<0.001). At the latest echocardiographic follow-up, homografts showed a significantly lower transpulmonary systolic pressure decrease (16 [interquartile range, 12–25] mm Hg) when compared with bioprostheses (28 [interquartile range, 18–41] mm Hg; mixed model P<0.001) and a similar degree of pulmonary regurgitation (degree 0-4) (1 [interquartile range, 0–2] versus 2 [interquartile range, 0–2]; mixed model P=0.19). At 9 years, freedom from structural valve deterioration and reintervention was 81.6% (95% CI, 71.5%–91.6%) versus 43.4% (95% CI, 23.6%–63.2%) in the homograft and bioprosthesis groups, respectively (adjusted hazard ratio, 0.27; 95% CI, 0.13–0.55; P<0.001). Conclusions-—When compared with bioprostheses, pulmonary homografts were associated lower transvalvular gradient during follow-up and were associated with a significantly lower risk of reintervention or structural valve degeneration.

Cite

CITATION STYLE

APA

Cocomello, L., Meloni, M., Rapetto, F., Baquedano, M., Ordonez, M. V., Biglino, G., … Caputo, M. (2019). Long-term comparison between pulmonary homograft versus bioprosthesis for pulmonary valve replacement in tetralogy of fallot. Journal of the American Heart Association, 8(24). https://doi.org/10.1161/JAHA.119.013654

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free