Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products - A 1-year randomized control trial

151Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Chronic utilization of a bio-incompatible peritoneal dialysis (PD) solution with acidic pH and a high content of glucose degradation product (GDP) has been implicated as a contributing cause of peritoneal failure. We compared a newly formulated solution of neutral pH and low levels of GDP to a standard PD solution. Methods. Fifty new PD patients were randomized to a conventional lactate-buffered fluid (control) and a pH neutral, lactate-buffered, low GDP solution (balance). Patients were followed for 12 months. Serum samples were assayed for C-reactive protein (CRP). PD effluent was collected and assayed for cancer antigen-125 (CA125) and hyaluronan (HA). Clinical end points were the residual renal function and dialysis adequacy indices. Results. After 52 weeks of treatment, PD fluid CA125 rose from 2.45 ± 0.96 to 14.30 ± 2.17U/ml (P < 0.001), and HA declined from 2.26 ± 0.60 to 1.45 ± 0.32μg/ml (P = 0.07) in the balance group. The balance group had a higher PD fluid CA-125 (14.30 ± 2.17 vs 7.36 ± 2.23U/ml, P = 0.007), lower HA (1.45 ± 0.32 vs 2.55 ± 0.32μg/ml, P = 0.007), and lower serum CRP level (1.77 ± 0.42 vs 7.73 ± 2.42mg/l, P = 0.026) than the control group at 52 weeks. There was no difference in dialysis adequacy indices, ultrafiltration volume, urine output, residual renal function, peritonitis rate or need of hospitalization in 1 year. Conclusion. As compared to conventional PD solution, the use of balance, a neutral pH, low GDP solution resulted in a superior profile of PDE mesothelial cell marker and a lower degree of systemic inflammation, and the difference was maintained for 1 year. It remains to be determined whether these effects could result in better long-term clinical outcome. © 2007 Oxford University Press.

Cite

CITATION STYLE

APA

Szeto, C. C., Chow, K. M., Lam, C. W. K., Leung, C. B., Kwan, B. C. H., Chung, K. Y., … Li, P. K. T. (2007). Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products - A 1-year randomized control trial. Nephrology Dialysis Transplantation, 22(2), 552–559. https://doi.org/10.1093/ndt/gfl559

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free