Numerical simulation of ISFET structures for biosensing devices with TCAD tools

28Citations
Citations of this article
76Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Ion Sensitive Field Effect Transistors (ISFETs) are one of the primitive structures for the fabrication of biosensors (BioFETs). Aiming at the optimization of the design and fabrication processes of BioFETs, the correlation between technological parameters and device electrical response can be obtained by means of an electrical device-level simulation. In this work we present a numerical simulation approach to the study of ISFET structures for bio-sensing devices (BioFET) using Synopsys Sentaurus Technology Computer-Aided Design (TCAD) tools. Methods: The properties of a custom-defined material were modified in order to reproduce the electrolyte behavior. In particular, the parameters of an intrinsic semiconductor material have been set in order to reproduce an electrolyte solution. By replacing the electrolyte solution with an intrinsic semiconductor, the electrostatic solution of the electrolyte region can therefore be calculated by solving the semiconductor equation within this region. Results: The electrostatic behaviour (transfer characteristics) of a general BioFET structure has been simulated when the captured target number increases from 1 to 10. The I D current as a function of the V DS voltage for different positions of a single charged block and for different values of the reference electrode have been calculated. The electrical potential distribution along the electrolyte-insulator-semiconductor structure has been evaluated for different molar concentrations of the electrolyte solution. Conclusions: We presented a numerical simulation approach to the study of Ion-Sensitive Field Effect Transistor (ISFET) structures for biosensing devices (BioFETs) using the Synopsys Sentaurus Technology Computer-Aided Design (TCAD) tools. A powerful framework for the design and optimization of biosensor has been devised, thus helping in reducing technology development time and cost. The main finding of the analysis of a general reference BioFET shows that there is no linear relationship between the number of charges and the current modulation. Actually, there is a strong position dependent effect: targets localized near the source region are most effective with respect to targets localized near the drain region. In general, even randomly distributed targets are more efficient with respect to locally grouped targets on the current modulation. Moreover, for the device at hand, a small positive biasing of the electrolyte solution, providing that the transistor goes on, will result in a greater enhancement of the current levels, still retaining a good sensitivity but greatly simplifying the operations of a real device.

Cite

CITATION STYLE

APA

Passeri, D., Morozzi, A., Kanxheri, K., & Scorzoni, A. (2015). Numerical simulation of ISFET structures for biosensing devices with TCAD tools. BioMedical Engineering Online, 14(2). https://doi.org/10.1186/1475-925X-14-S2-S3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free