Chinesisation, adaptation and validation of the Chelsea Critical Care Physical Assessment Tool in critically ill patients: A cross-sectional observational study

8Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

Abstract

To translate and adapt the Chelsea Critical Care Physical Assessment Tool (CPAx) into Chinese version (‘CPAx-Chi’), test the reliability and validity of CPAx-Chi, and verify the cut-off point for the diagnosis of intensive care unit-acquired weakness (ICU-AW). Cross-sectional observational study. Forward and back translation, cross-cultural adaptation and pretesting of CPAx into CPAx-Chi were based on the Brislin model. Participants were recruited from the general ICU of five third-grade class-A hospitals in western China. Two hundred critically ill adult patients (median age: 53 years; 64% men) with duration of ICU stay ≥48 hours and Glasgow Coma Scale ≥11 were included in this study. Two researchers simultaneously and independently assessed eligible patients using the Medical Research Council Muscle Score (MRC-Score) and CPAx-Chi. The content validity index of items was 0.889. The content validity index of scale was 0.955. Taking the MRC-Score scale as standard, the criterion validity of CPAx-Chi was r=0.758 (p<0.001) for researcher A, and r=0.65 (p<0.001) for researcher B. Cronbach’s α was 0.939. The inter-rater reliability was 0.902 (p<0.001). The area under the receiver operating characteristic curves of CPAx-Chi for diagnosing ICU-AW based on MRC-Score ≤48 were 0.899 (95% CI 0.862 to 1.025) and 0.874 (95% CI 0.824 to 0.925) for researcher B. The best cut-off point for CPAx-Chi for the diagnosis of ICU-AW was 31.5. The sensitivity was 87% and specificity was 77% for researcher A, whereas it was 0.621, 31.5, 75% and 87% for researcher B, respectively. The consistency was high when taking CPAx-Chi ≤31 and MRC-Score ≤48 as the cut-off points for the diagnosis of ICU-AW. Cohen’s kappa=0.845 (p=0.02) in researcher A and 0.839 (p=0.04) for researcher B. CPAx-Chi demonstrated content validity, criterion-related validity and reliability. CPAx-Chi showed the best accuracy in assessment of patients at risk of ICU-AW with good sensitivity and specificity at a recommended cut-off of 31.

Cite

CITATION STYLE

APA

Zhang, Z., Wang, G., Wu, Y., Guo, J., Ding, N., Jiang, B., … Tian, J. (2021). Chinesisation, adaptation and validation of the Chelsea Critical Care Physical Assessment Tool in critically ill patients: A cross-sectional observational study. BMJ Open, 11(4). https://doi.org/10.1136/bmjopen-2020-045550

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free