Pilot Study of AI-Assisted ANA Immunofluorescence Reading—Comparison with Classical Visual Interpretation

2Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

Background: Antinuclear antibodies (ANAs) play a crucial role in diagnosing systemic autoimmune rheumatic diseases, particularly systemic lupus erythematosus. The recommended standard for ANA detection is indirect immunofluorescence testing (IIFT) using human epithelial (HEp-2) cells. Since visual interpretation (VI) of IIFT images is time-consuming and labor-intensive, research is focusing on automated interpretation systems that use artificial intelligence (AI). Methods: Consecutive serum samples (number of sera = 143) from routine clinical care were collected from patients visiting our tertiary rheumatology center. ANA were detected by IIFT with visual interpretation and compared with IIFT using the AI-based interpretation system akiron® NEO (Medipan, 15827 Blankenfelde-Mahlow, Germany). ANA titer levels and patterns were analyzed according to the Competent Level of the International Consensus on ANA Pattern classification. Results: Agreement of positive/negative ANA discrimination between AI-aided and VI-IIFT at the recommended cut-off of 80 was good (Cohen’s kappa [κ] 0.69) but significantly different (McNemar test, p < 0.0001). At a cut-off of ≥1/80, the agreement was improved (κ 0.76) and the difference between both methods was non-significant (p = 1.0000). The ANA pattern recognition agreement between both approaches was moderate (κ = 0.54). The direct comparison using only the akiron® NEO HEp-2 cell ANA assay revealed a good agreement (0.67), which improved to very good (κ = 0.80) when differences between ANA patterns anti-cell (AC)4/5 and AC2 were neglected. Notably, titer levels in the automated evaluations were frequently assessed at higher values than in the gold standard interpretation. Conclusions: Our study demonstrates a good agreement for positive/negative ANA discrimination. ANA pattern recognition by AI-aided interpretation showed moderate to very good agreement with VI. Further research and algorithm refinement (e.g., improved pattern recognition and titer calibration) are necessary to support its future implementation as a reliable screening method.

Cite

CITATION STYLE

APA

Mayr, S., Dollinger, M., Ehrenstein, B., Günther, F., Krammer, O., Schuster, A., … Fleck, M. (2025). Pilot Study of AI-Assisted ANA Immunofluorescence Reading—Comparison with Classical Visual Interpretation. Journal of Clinical Medicine, 14(19). https://doi.org/10.3390/jcm14196924

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free