Background: Heterogeneity regarding dosimetry and reporting of endovenous laser ablation (EVLA) mandates the development of a standardized protocol. This study presents the mid-term results of EVLA with 1940 nm-laser and radial-fibre, supported by a four-zone dosimetry tool. Materials and methods: Four anatomical dosimetry zones for great saphenous veins (GSV) and two for small saphenous veins (SSV) were defined with set power levels. Zone-1G (4 W) extended from the inguinal ligament to the apex of femoral triangle, Zone-2G (4 W) from the apex of femoral triangle to the upper border of patella. Zone-3G (3 W) from the patella to the tibial tuberosity. Zone-4G (2 W) extended from the tibial tuberosity to the ankle. Zone-1S from the sapheno-popliteal junction to the tibial tuberosity. Zone-2S from the tibial tuberosity to the ankle. Power was increased by 1 W for veins >10 mm and decreased by 1 W when fibre sticking was encountered. Pullback-velocity was max. 1 mm/s. Results: A total of 152 consecutive patients (185 procedures) were recruited. Mean follow-up time was 11.9 months. Mean linear endovenous energy density for GSV was Zone-1G:42 J/cm, Zone-2G:33 J/cm, Zone-3G:27 J/cm, Zone-4G:22 J/cm, Zone-1S:34 J/cm, Zone-2S:27 J/cm. Occlusion rates were 98.9% (1-month) and 93.7% (12-months). Complications at 1 M were low, namely laser-induced paraesthesia (LIP) 2.2% and endovenous heat-induced thrombosis (EHIT) 1.6%. Persistent LIP (12 M) was observed in 0.5%. Conclusion: The proposed four-zone guiding tool is a step towards standardizing dosimetry and documentation for EVLA with 1940 nm. This strategy shows good mid-term results with minimal complications. Long-term follow-up and application in further centres are necessary to prove its reproducibility. Such a guiding tool could improve the ability to analyse, compare and review different EVLA wavelengths and fibre types.

Cite

CITATION STYLE

APA

Setia, A., Dikic, S., Demhasaj, S., Schmitz-Rixen, T., Sroka, R., & Schmedt, C. G. (2023). Prospects of Endovenous Laser Ablation (EVLA) Standardization—Mid-Term Results of a Four-Zone Dosimetry Guiding Tool for 1940 nm Laser. Journal of Clinical Medicine, 12(13). https://doi.org/10.3390/jcm12134313

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free