A simple high-performance liquid chromatographic assay for concurrent quantification of lumefantrine and efavirenz in human plasma from malaria–HIV co-infected individuals

  • Adegbola A
  • Ogboye R
  • Soyinka J
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BackgroundAs per current treatment guidelines, artemether-lumefantrine and efavirenz-based antiretroviral therapy are recommended drugs for falciparum malaria and human immunodeficiency virus (HIV) infections, respectively. A liquid chromatography-ultraviolet detection method for simultaneous quantification of lumefantrine and efavirenz was developed and validated for efficacy and pharmacokinetic clinical studies. Lumefantrine and efavirenz were separated using a 100 x 4.6 mm x 3 & mu;m Fortis C-18 chromatographic column, and a multistep gradient mobile phase. Calibration curves were obtained with a series of standard solutions containing known concentrations of the chemical reference of both analytes prepared concomitantly in drug-free plasma. The assay was validated within the calibration ranges of 78.125-20,000 ng/mL for lumefantrine and 187.15-24,000 ng/mL for efavirenz. Stability assessment was carried out with or without heating the quality control sample to 58 & DEG;C for 45 min. The method was employed to measure the plasma concentrations of lumefantrine and efavirenz in a study conducted among malaria-HIV co-infected patients.ResultLumefantrine and efavirenz were well separated from each other and from the biological matrix. The method demonstrated a good recovery of 72.64% for lumefantrine and 117.17% for efavirenz. The intra- and inter-day accuracy presented as 95.36-105.14% for lumefantrine and 104.11-115% for efavirenz and precision ranged from 1.15 to 6.45% for lumefantrine and 0.43 to 13.12 for efavirenz, were within & PLUSMN; 15% at the three quality control levels. The analytes from both quality control lots and samples collected from HIV-malaria co-infected individuals were found to be stable post-deactivation of infectious virus by heating to 58 & DEG;C for 45 min.ConclusionThe assay is accurate, precise and shown to simultaneously measure the lumefantrine and EFV in human plasma. PU - SPRINGER PI - NEW YORK PA - ONE NEW YORK PLAZA, SUITE 4600, NEW YORK, NY, UNITED STATES

Cite

CITATION STYLE

APA

Adegbola, A. J., Ogboye, R. M., Soyinka, J. O., & Bolaji, O. O. (2023). A simple high-performance liquid chromatographic assay for concurrent quantification of lumefantrine and efavirenz in human plasma from malaria–HIV co-infected individuals. Future Journal of Pharmaceutical Sciences, 9(1). https://doi.org/10.1186/s43094-023-00508-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free