High Sensitive Neutron-detection by using a Self-activation of Iodine-containing Scintillators for the Photo-neutron Monitoring around X-ray Radiotherapy Machines

6Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A novel method for evaluating the neutron dose-equivalent as well as neutron fluence around high-energy X-ray radiotherapy machines has been proposed and examined by using the self-activation of a CsI scintillator. Several filtering conditions were used to extract energy information of the neutron field. The shapes of neutron energy spectra were assumed to be practically unchanged at each three energy regions (thermal, epi-thermal and fast regions) for different irradiations around an X-ray linac whose acceleration potential was fixed to be a certain value. In order to know the actual neutron energy spectrum, an unfolding process was carried out for saturated activities of 128I generated inside the CsI scintillator under different filtering conditions; the response function matrix for each filtering condition was calculated by a Monte Carlo simulation. As the result, neutron dose-equivalent was estimated to be 0.14 [mSv/Gy] at 30 cm from the isocenter of linac. It has been revealed that fast neutron component dominated the total dose-equivalent.

Cite

CITATION STYLE

APA

Nohtomi, A., Wakabayashi, G., Kinoshita, H., Honda, S., Kurihara, R., Fukunaga, J., … Nakamura, K. (2016). High Sensitive Neutron-detection by using a Self-activation of Iodine-containing Scintillators for the Photo-neutron Monitoring around X-ray Radiotherapy Machines. In Proceedings of International Symposium on Radiation Detectors and Their Uses, ISRD 2016. Physical Society of Japan. https://doi.org/10.7566/JPSCP.11.050002

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free