False-positive recalls in the prospective Malmö Breast Tomosynthesis Screening Trial

9Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: To evaluate the total number of false-positive recalls, including radiographic appearances and false-positive biopsies, in the Malmö Breast Tomosynthesis Screening Trial (MBTST). Methods: The prospective, population-based MBTST, with 14,848 participating women, was designed to compare one-view digital breast tomosynthesis (DBT) to two-view digital mammography (DM) in breast cancer screening. False-positive recall rates, radiographic appearances, and biopsy rates were analyzed. Comparisons were made between DBT, DM, and DBT + DM, both in total and in trial year 1 compared to trial years 2 to 5, with numbers, percentages, and 95% confidence intervals (CI). Results: The false-positive recall rate was higher with DBT, 1.6% (95% CI 1.4; 1.8), compared to screening with DM, 0.8% (95% CI 0.7; 1.0). The proportion of the radiographic appearance of stellate distortion was 37.3% (91/244) with DBT, compared to 24.0% (29/121) with DM. The false-positive recall rate with DBT during trial year 1 was 2.6% (95% CI 1.8; 3.5), then stabilized at 1.5% (95% CI 1.3; 1.8) during trial years 2 to 5. The percentage of stellate distortion with DBT was 50% (19/38) trial year 1 compared to 35.0% (72/206) trial years 2 to 5. Conclusions: The higher false-positive recall rate with DBT compared to DM was mainly due to an increased detection of stellate findings. The proportion of these findings, as well as the DBT false-positive recall rate, was reduced after the first trial year. Clinical relevance statement: Assessment of false-positive recalls gives information on potential benefits and side effects in DBT screening. Key Points: • The false-positive recall rate in a prospective digital breast tomosynthesis screening trial was higher compared to digital mammography, but still low compared to other trials. • The higher false-positive recall rate with digital breast tomosynthesis was mainly due to an increased detection of stellate findings; the proportion of these findings was reduced after the first trial year.

Cite

CITATION STYLE

APA

Johnson, K., Olinder, J., Rosso, A., Andersson, I., Lång, K., & Zackrisson, S. (2023). False-positive recalls in the prospective Malmö Breast Tomosynthesis Screening Trial. European Radiology, 33(11), 8089–8099. https://doi.org/10.1007/s00330-023-09705-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free