Bubble size distribution in a bubble column applied to aquaculture systems

27Citations
Citations of this article
64Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Bubble size distribution affects the gas-liquid mass transfer rates during aeration and foam fractionation processes employed in recirculating aquacultural systems. The effects of air flow rate, protein concentration and air stone pore size on bubble characterization were investigated. Bubble size was measured photographically in conjunction with image-processing techniques. The study indicated that bubble size increased with air flow rate and air stone pore size, but decreased with protein concentration. Within the tested range of these variables, the geometric diameters of the majority of the bubbles (90%) were within the range of 0·5-3·0 mm, and the bubble sizes followed a normal distribution. © 1993.

Cite

CITATION STYLE

APA

Chen, S., Timmons, M. B., Aneshansley, D. J., & Bisogni, J. J. (1992). Bubble size distribution in a bubble column applied to aquaculture systems. Aquacultural Engineering, 11(4), 267–280. https://doi.org/10.1016/0144-8609(92)90009-M

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free