The validity of using one force platform to quantify whole-body forces, velocities, and power during a plyometric push-up

4Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Previous studies have typically measured velocity and power parameters during the push-up, either using one or two force platforms. The purpose of the study was to compare the force, velocity, and power parameters between the one-force-platform method and the two-force-platform method during plyometric push-ups. Methods: Thirty-four physically active young adults participated in the study to perform the plyometric push-up. For the two-force-platform calculation method, the forces applied to the feet and hands were both measured. For the one-force-platform calculation method, the forces applied to the feet were assumed to be constant, while the forces applied to hands were measured by one force platform. Whole-body linear velocities were calculated based on the impulse and momentum theorem. Whole-body power was calculated as the product of the whole-body forces and velocities. Results: The one-force-platform method overestimated the whole-body velocities and power compared with the two-force-platform method (1.39 ± 0.37 m/s vs. 0.90 ± 0.23 m/s, Cohen’s d = 1.59, p < 0.05; 1.63 ± 0.47 W/body weight vs. 1.03 ± 0.29 W/body weight, Cohen’s d = 1.49, p < 0.05). These differences were caused by the decreased forces applied to the feet compared to the initial value throughout most of the push-up phase. Large to perfect correlations (r = 0.55 – 0.99) were found for most variables between the two-force-platform and one-force-platform methods. Previous findings of push-up velocities and power using the two-force-platform and one-force-platform methods should be compared with caution. While the two-force-platform method is recommended, linear regression equations may be used to predict velocities and power parameters obtained from one force platform. Conclusions: For those professionals who need to accurately quantify kinetic variables during the plyometric push-up, the two-force-platform method should be considered.

Author supplied keywords

Cite

CITATION STYLE

APA

Sha, Z., & Dai, B. (2021). The validity of using one force platform to quantify whole-body forces, velocities, and power during a plyometric push-up. BMC Sports Science, Medicine and Rehabilitation, 13(1). https://doi.org/10.1186/s13102-021-00330-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free