Abstract
Purpose To assess if fully automated localization of the aorta can be achieved using phase contrast (PC) MR images. Materials and Methods PC cardiac-gated MR images were obtained as part of a large population-based study. A fully automated process using the Hough transform was developed to localize the ascending aorta (AAo) and descending aorta (DAo). The study was designed to validate this technique by determining: (i) its performance in localizing the AAo and DAo; (ii) its accuracy in generating AAo flow volume and DAo flow volume; and (III) its robustness on studies with pathological abnormalities or imaging artifacts. Results The algorithm was applied successfully on 1884 participants. In the randomly selected 50-study validation set, linear regression shows an excellent correlation between the automated (A) and manual (M) methods for AAo flow (r = 0.99) and DAo flow (r = 0.99). Bland-Altman difference analysis demonstrates strong agreement with minimal bias for: AAo flow (mean difference [A-M] = 0.47 ± 2.53 mL), and DAo flow (mean difference [A-M] = 1.74 ± 2.47 mL). Conclusion A robust fully automated tool to localize the aorta and provide flow volume measurements on phase contrast MRI was validated on a large population-based study. © 2013 Wiley Periodicals, Inc. © 2013 Wiley Periodicals, Inc.
Author supplied keywords
Cite
CITATION STYLE
Goel, A., McColl, R., King, K. S., Whittemore, A., & Peshock, R. M. (2014). Fully automated tool to identify the aorta and compute flow using phase-contrast MRI: Validation and application in a large population based study. Journal of Magnetic Resonance Imaging, 40(1), 221–228. https://doi.org/10.1002/jmri.24338
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.