Abstract
Purpose: To evaluate the effectiveness and safety of a modified approach using the Ex-PRESS® implant combined with a scleral pocket in the management of secondary open-angle glaucoma in hereditary transthyretin amyloidosis (hATTR) at our department. Methods: This was a retrospective analysis. The primary endpoints included Intraocular pressure (IOP) evaluation (baseline, 1st day, 1st week, 1, 3, 6, 12 months and at last follow-up) and number of hypotensive drugs (baseline, 6th, 12th months and at last follow-up). As secondary endpoints surgical complications, the need for additional glaucoma surgery and LogMAR BCVA were evaluated. Qualified and complete success were defined as ≥ 30% IOP decrease from baseline, with or without additional medications, respectively. The minimum follow-up was 12 months. Results: A total of 32 eyes were included with a mean follow-up of 2.4±2.9 years. IOP decreased significantly from baseline (27.4 ±4.4 mmHg) to 1st day (5.00±2.9 mmHg), 1st week (6.9±4.1 mmHg), 1st month (11.7±7.8 mmHg), 3rd month (11.6±6.1 mmHg), 6th month (13.1±6.8 mmHg), 12th month (12.0±3.5 mmHg) and last visit (11.8±2.4 mmHg), p0.001. There was also a significant reduction in the number of antiglaucoma medications from baseline (3.8±0.6) and last follow-up (0.4±0.8), p0.001. LogMAR BCVA remained stable (0.25±0.26 at baseline and 0.25±0.24 at last follow-up), p=0.767. Transient hypotony occurred in 17 eyes (53.1%), but only 11 (34.4%) exhibited anterior chamber shallowing and needed additional care, namely cycloplegic drops and viscoelastic injection. Complete surgical success was achieved in 22 eyes (68.8%) and qualified success in 6 eyes (18.8%). Four eyes (12.5%) needed additional glaucoma surgery. Conclusion: The modified ExPRESS® technique appears to be effective, especially when low levels of IOP are required. Additionally, fewer anti-glaucoma drugs were necessary. In the other hand, hypotony was a common side effect with this procedure, although all patients were properly handled, preserving the surgical outcomes.
Author supplied keywords
Cite
CITATION STYLE
Vieira, R., Marta, A., Ferreira, A., Figueiredo, A., Reis, R. F., Sampaio, I., & Menéres, M. J. (2023). Modified technique of ex-press® filtration device combined with a scleral pocket for hereditary transthyretin amyloidosis (Hattr) secondary open-angle glaucoma. Clinical Ophthalmology, 17, 403–411. https://doi.org/10.2147/OPTH.S394360
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.