Abstract
Determination of toxic glycols and alcohols in an emergency setting requires a rapid yet accurate and reliable method. To simultaneously determine diethylene glycol (DEG) along with ethylene glycol, methanol, isopropanol, acetone, and ethanol, we modified a previously developed gas chromatographic (GC) method. The system used a Hewlett-Packard 6890 GC with EPC, a Gooseneck splitless liner, and an Rtx-200 capillary column (30 m x 0.53-mm i.d., 3 mm). After serum samples were deproteinized using ultrafiltration (Millipore Ultrafree®-MC), 1 mL of the protein-free filtrate was manually injected into the GC. Internal standards for alcohols (and acetone) and glycols were n-propanol and 1,3-butanediol, respectively. All compounds eluted within 3.5 min (linear temperature gradient from 40 to 260°C); total run time was 6.5 min. Limit of detection and linear range for all compounds were 1 or 2.5 mg/dL and 0-500 mg/dL, respectively. In addition, there was no interference from propionic acid, propylene glycol, and 2,3-butanediol. The modifications in the equipment and temperature program allowed increased resolution and thus, detection and reliable quantitation of DEG and other common toxic glycols and alcohols of clinical interest.
Cite
CITATION STYLE
Williams, R. H., Shah, S. M., Maggiore, J. A., & Erickson, T. B. (2000). Simultaneous detection and quantitation of diethylene glycol, ethylene glycol, and the toxic alcohols in serum using capillary column gas chromatography. Journal of Analytical Toxicology, 24(7), 621–626. https://doi.org/10.1093/jat/24.7.621