Study design: This is a retrospective chart review. Objectives: To identify the incidence of, and variables correlated with, femoral ring allograft (FRA) fracture following anterior lumbar interbody fusion (ALIF). Methods: All patients who underwent ALIF using FRAs at an academic institution over 10 years were included. Postoperative radiographs were reviewed by both the primary and senior authors; fracture and no-fracture groups were created for comparison. Patient and surgical characteristics were extracted from electronic medical records. Frequency data comparisons were performed using contingency table analysis; comparisons of means were analyzed for continuous variables. A multivariate linear regression model was developed using screw use, graft height <12 mm, index level, and weight as variables. Results: A total of 76 FRAs in 59 patients were identified, 13 (17%) of which fractured. Age, sex, smoking status, use of buttress screws, weight, index level, and presence of spondylolisthesis were not correlated with incidence of fracture (P >.05). There was a significant correlation between the height of FRA and incidence of fracture; 2% (1/52) of grafts ≥12 mm and 50% (12/24) of grafts <12 mm fractured (P <12 mm is an independent risk factor for FRA fracture in patients undergoing ALIF, and their use should be avoided in ALIF procedures.
CITATION STYLE
Philipp, T., Radoslovich, S. S., & Yoo, J. U. (2021). Risk Factors Associated With Femoral Ring Allograft Breakage in ALIF. Global Spine Journal, 11(1), 57–62. https://doi.org/10.1177/2192568219890294