Introducing MC-MICAP-MS: using a N2-based plasma ion source for Sr isotope abundance ratio measurements

5Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

High-precision metal(loid) isotope abundance ratios are a powerful research tool across various disciplines. These ratios are typically measured using multi-collector mass spectrometry with ion sources such as gas source, thermal ionization, or inductively coupled plasma (i.e., IRMS, TIMS, and MC-ICP-MS). This study presents the first integration of the recently developed microwave inductively coupled atmospheric-pressure plasma (MICAP) ion source, which sustains a plasma using N2, with a multi-collector mass spectrometer and offers the first characterization of the resulting MC-MICAP-MS instrument for high-precision metal isotope abundance ratio measurements. The performance of the MC-MICAP-MS instrument was evaluated by measuring Sr isotope abundance ratios and directly comparing the results with those obtained using established technology (i.e., MC-ICP-MS) with an Ar-ICP as the ion source. Initial results using the MICAP ion source show that the 87Sr/86Sr intensity ratio precision (approx. 0.007%) and the repeatability of the 87Sr/86Sr intensity ratio (approx. 0.010%), as well as the intermediate precision of the conventional 87Sr/86Sr isotope abundance ratio (approx. 0.0013%) are fully comparable to those of conventional MC-ICP-MS systems. The instrumental isotopic fractionation (IIF) observed for the new MC-MICAP-MS instrument was predominantly mass-dependent for Sr. This allowed the successful application of common IIF correction strategies, such as internal normalisation and standard-sample bracketing, for the determination of Sr isotope abundance ratios. The conventional 87Sr/86Sr isotope abundance ratios and δ88Sr/86SrSRM987 values measured for various geological and biological reference materials (i.e., seawater, basalt, slate, and bone) using MC-MICAP-MS were consistent with previously reported values obtained from established technologies such as TIMS and MC-ICP-MS. Overall, this study demonstrates that MICAP is an applicable and viable alternative ion source for multi-collector mass spectrometry, maintaining both double-focusing properties and high-precision performance without compromising the accuracy and reliability of the measurement results.

Cite

CITATION STYLE

APA

Retzmann, A., Menon, A., & Wieser, M. E. (2025). Introducing MC-MICAP-MS: using a N2-based plasma ion source for Sr isotope abundance ratio measurements. Journal of Analytical Atomic Spectrometry, 40(10), 2803–2815. https://doi.org/10.1039/d5ja00271k

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free