Abstract
The paper presents an analysis of overvoltages caused by a direct lightning strike in intrusion detection system equipped with underground radiating cable sensors. Waveforms of currents and voltages in the system components are calculated using analytical formulas basing on a transmission-line model in the frequency domain. The time-domain waveforms are computed using the inverse fast Fourier transform (IFFT). Three network configurations of the intrusion detection system are analyzed.
Author supplied keywords
Cite
CITATION STYLE
Aniserowicz, K. (2019). Analytical calculations of surges caused by direct lightning strike to underground intrusion detection system. Bulletin of the Polish Academy of Sciences: Technical Sciences, 67(2), 263–269. https://doi.org/10.24425/bpas.2019.128118
Register to see more suggestions