Measurement of stress concentration factor for shoulder fillet on flat plate under axial tension using photoelasticity method and FEA

0Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Many researchers have made attempt to investigate stress concentration factor (SCF) for different discontinuities under different loading conditions and applications, but still failures of components take place which having discontinuities. Number of applications under which the components or parts working under tensile loading. Here, efforts are made to investigate the SCF of flat plate with shoulder fillet under axial tension loading using the approach of Photoelasticity for different D/d ratios. The Finite Element Analysis (FEA) approach used to validate the results of experimentation and found that the results are reasonably at acceptable level. One can utilize the outcome of this research for similar application having same discontinuity and loading condition.

Cite

CITATION STYLE

APA

Patel, B., & Prajapati, H. (2019). Measurement of stress concentration factor for shoulder fillet on flat plate under axial tension using photoelasticity method and FEA. International Journal of Innovative Technology and Exploring Engineering, 8(12), 4234–4244. https://doi.org/10.35940/ijitee.L2695.1081219