Abstract
Spin squeezing can increase the sensitivity of interferometric measurements of small signals in large spin ensembles beyond the standard quantum limit. In many practical settings, the ideal metrological gain is limited by imperfect readout of the sensor. To overcome this issue, protocols based on time reversal of unitary one-axis-twist (OAT) spin-squeezing dynamics have been proposed. Such protocols mitigate readout noise and, when implemented using cavity feedback, have been argued to also be robust against dissipation as long as the collective cooperativity of the system is sufficiently large [Davis, Phys. Rev. Lett. 116, 053601 (2016)0031-900710.1103/PhysRevLett.116.053601]. Here, we perform a careful systematic study of dissipative effects on three different implementations of a OAT twist-untwist sensing scheme (based on symmetric as well as asymmetric cavity feedback and on a Tavis-Cummings interaction). Our full treatment shows that the three approaches have markedly different properties and resilience when subject to dissipation. Moreover, the metrological gain for an implementation using symmetric cavity feedback is more sensitive to undesired dissipation than was previously appreciated.
Cite
CITATION STYLE
Koppenhöfer, M., & Clerk, A. A. (2023). Revisiting the impact of dissipation on time-reversed one-axis-twist quantum-sensing protocols. Physical Review Research, 5(4). https://doi.org/10.1103/PhysRevResearch.5.043279