Identifying Three Phase Induction Motor Equivalent Circuit Parameters from Nameplate Data by Different Analytical Methods

  • Helonde A
  • Mankar M
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

The induction motor equivalent circuit parameters are required for many performance and planning studies involving induction motors. These parameters are typically calculated from standardized motor performance tests, such as the no load, full load, and locked rotor tests. However, standardized test data is not typically available to the end user. Alternatively, the equivalent circuit parameters may be estimated based on published performance data for the motor. Methodologies for obtaining the parameters of the equivalent circuit for an induction motor from the information on the nameplate and an analysis is presented so that the typical parameters of an equivalent circuit can be readily estimated.

Cite

CITATION STYLE

APA

Helonde, A. R., & Mankar, Mr. M. (2019). Identifying Three Phase Induction Motor Equivalent Circuit Parameters from Nameplate Data by Different Analytical Methods. International Journal of Trend in Scientific Research and Development, Volume-3(Issue-3), 642–645. https://doi.org/10.31142/ijtsrd22934