Prescreening Evaluation of a Brush-Based Faecal Immunochemical Test for Haemoglobin

  • Young G
  • John D
  • Cole S
  • et al.
N/ACitations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: To undertake a prescreening evaluation of a new brush-based faecal immunochemical test for haemoglobin, relative to a traditional spatula-sampling immunochemical test. SETTING: Patients aged between 24 and 90 years, scheduled to undergo diagnostic colonoscopy in two major urban hospitals, for a range of clinical indications. DESIGN: Patients sampled three stools using a spatula for the reference FlexSure OBT test and two stools using a brush for the InSure test; order of sampling was randomised. Faecal haemoglobin was quantified by a modified InSure in a subset of patients to determine whether brush-sampling allowed discrimination between groups. MAIN OUTCOME MEASURES: Sensitivity for cancer or adenoma; false-positive rate in normals. Faecal haemoglobin levels. Preference for sampling method. RESULTS: InSure and FlexSure OBT did not differ in their sensitivities for cancer (27/36, 75% vs 29/36, 80.5%, respectively), adenomas >or= 10 mm (12/29, 41.4% vs 13/29, 44.8%) or adenomas <10 mm (each 8/56, 14.3%). Likewise, false-positive rates in normals were similar: 4/179 (2.2%) and 5/179 (2.8%) respectively (specificities of 97.8% and 97.2%, respectively). Levels of faecal haemoglobin were highest in those with cancers; those with adenomas had intermediate levels which were also significantly higher than those in normals. The brush sampling method was preferred by 38/46 (82.6%), while 4/46 (8.7%) preferred the spatula (p<0.00001). CONCLUSIONS: InSure is as sensitive and specific as FlexSure OBT for faecal haemoglobin. The novel stool-sampling method of InSure allows discrimination between normals and classes of neoplasia, and is highly preferred. The brush-sampling faecal immunochemical test InSure should now be evaluated in a screening population.

Cite

CITATION STYLE

APA

Young, G. P., John, D. J. B. S., Cole, S. R., Bielecki, B. E., Pizzey, C., Sinatra, M. A., … Morcom, J. (2003). Prescreening Evaluation of a Brush-Based Faecal Immunochemical Test for Haemoglobin. Journal of Medical Screening, 10(3), 123–128. https://doi.org/10.1177/096914130301000305

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free