Clinical Evaluation of Assays for Plasma Renin Activity and Aldosterone Measurement by Liquid Chromatography-Tandem Mass Spectrometry

9Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Aldosterone and renin are pivotal hormones in the regulation of salt and water homeostasis and blood pressure. Measurement of renin and aldosterone in serum/plasma is essential for the investigation of primary hyperaldosteronism (PA) and monitoring of glucocorticoid replacement therapy. Methods: We report 2 LC-MS/MS methods developed to measure aldosterone and plasma renin activity (PRA). PRA was determined by endogenous enzymatic generation of angiotensin I using 150 μL of sample. Generated angiotensin I was purified by solid phase extraction prior to chromatographic separation and mass spectrometry. Aldosterone measurement required 300 μL of sample extracted with MTBE prior to LC-MS/MS analysis. Results: The PRA method was linear (1.2-193 nmol/L), sensitive (LLOQ = 1.2 nmol/L), precise (CV = 4.1%), and specific (no cross reactivity for a number of structurally similar steroids). Dilutional linearity and recovery (84%) were acceptable. Accuracy was confirmed by comparison against our current RIA method. The aldosterone method had equally acceptable performance characteristics. Reference ranges in 110 healthy normotensive subjects were: PRA 0.2-3.7 nmol/L/h and aldosterone 50-950 pmol/L. Consecutive patients (n = 62) with adrenal incidentalomas shown to have no functional adrenal disease; their post overnight 1 mg dexamethasone test values were: PRA 0.2-2.6 nmol/L/h and aldosterone 55-480 pmol/L. Serum aldosterone values after 2 liter saline suppression were - normal subjects (n = 17): 78-238 pmol/L and confirmed primary hyperaldosteronism (n = 25): 131-1080 pmol/L. Conclusions: We have developed robust assays for PRA and aldosterone with appropriate clinical evaluation. These assays are now in routine practice in the UK.

Cite

CITATION STYLE

APA

Gibbons, S. M., Field, H. P., Fairhurst, A., Fleming, A., Ford, C., Williams, E. L., … Barth, J. H. (2021). Clinical Evaluation of Assays for Plasma Renin Activity and Aldosterone Measurement by Liquid Chromatography-Tandem Mass Spectrometry. Journal of Applied Laboratory Medicine, 6(3), 668–678. https://doi.org/10.1093/jalm/jfaa177

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free