Abstract
Background: Reducing neointima formation and atherosclerosis are key goals in preventing late vein graft failure. Although pharmacologic and mechanical solutions have been proposed, the demonstration that these influence both aspects of vein graft pathology have been lacking. Supporting grafts externally with an oversized, highly porous polyester stent dramatically reduces neointima formation in normocholesterolemic pigs. However, its effects in the presence of hypercholesterolemia are unknown. Methods: We compared wall thickening, cholesterol concentration, foam-cell formation, and the expression of the leukocyte adhesion molecule vascular cell adhesion molecule 1 after 3 months in stented and unstented saphenous vein interposition grafts into the carotid arteries of pigs fed cholesterol to cause modest hypercholesterolemia (11.2 ± 1.2 mmol/L). Results: Stenting reduced neointima formation from 5.6 ± 0.4 to 1.2 ± 0.2 mm2 (n = 7; P
Cite
CITATION STYLE
Angelini, G. D., Lloyd, C., Bush, R., Johnson, J., & Newby, A. C. (2002). An external, oversized, porous polyester stent reduces vein graft neointima formation, cholesterol concentration, and vascular cell adhesion molecule 1 expression in cholesterol-fed pigs. Journal of Thoracic and Cardiovascular Surgery, 124(5), 950–956. https://doi.org/10.1067/mtc.2002.127004