A Wearable Ultrasonic Neurostimulator - Part II: A 2D CMUT Phased Array System with a Flip-Chip Bonded ASIC

33Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A 2D ultrasonic array is the ultimate form of a focused ultrasonic system, which enables electronically focusing beams in a 3D space. A 2D array is also a versatile tool for various applications such as 3D imaging, high-intensity focused ultrasound, particle manipulation, and pattern generation. However, building a 2D system involves complicated technologies: fabricating a 2D transducer array, developing a pitch-matched ASIC, and interconnecting the transducer and the ASIC. Previously, we successfully demonstrated 2D capacitive micromachined ultrasonic transducer (CMUT) arrays using various fabrication technologies. In this paper, we present a 2D ultrasonic transmit phased array based on a 32 × 32 CMUT array flip-chip bonded to a pitch-matched pulser ASIC for ultrasonic neuromodulation. The ASIC consists of 32 × 32 unipolar high-voltage (HV) pulsers, each of which occupies an area of 250 μm × 250 μm. The phase of each pulser output is individually programmable with a resolution of 1/f_C/16, where f_C is less than 10 MHz. This enables the fine granular control of a focus. The ASIC was fabricated in the TSMC 0.18-μm HV BCD process within an area of 9.8 mm × 9.8 mm, followed by a wafer-level solder bumping process. After flip-chip bonding an ASIC and a CMUT array, we identified shorted elements in the CMUT array using the built-in test function in the ASIC, which took approximately 9 minutes to scan the entire 32 × 32 array. A compact-form-factor wireless neural stimulator system - only requiring a connected 15-V DC power supply - was also developed, integrating a power management unit, a clock generator, and a Bluetooth Low-Energy enabled microcontroller. The focusing and steering capability of the system in a 3D space is demonstrated, while achieving a spatial-peak pulse-average intensity (I_SPPA) of 12.4 and 33.1 W/ cm^2; and a 3-dB focal volume of 0.2 and 0.05 mm^3 - at a depth of 5 mm - at 2 and 3.4 MHz, respectively. We also characterized transmission of ultrasound through a mouse skull and compensated the phase distortion due to the skull by using the programmable phase-delay function in the ASIC, achieving 10% improvement in pressure and a tighter focus. Finally, we demonstrated a ultrasonic arbitrary pattern generation on a 5 mm × 5 mm plane at a depth of 5 mm.

Cite

CITATION STYLE

APA

Seok, C., Adelegan, O. J., Biliroglu, A. O., Yamaner, F. Y., & Oralkan, O. (2021). A Wearable Ultrasonic Neurostimulator - Part II: A 2D CMUT Phased Array System with a Flip-Chip Bonded ASIC. IEEE Transactions on Biomedical Circuits and Systems, 15(4), 705–718. https://doi.org/10.1109/TBCAS.2021.3105064

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free