Dosimetric comparison of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left-sided chest wall and lymphatic irradiation

11Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: The aim of this study was to compare five different techniques for chest wall (CW) and lymphatic irradiation in patients with left-sided breast carcinoma. Methods: Three-dimensional conformal radiotherapy (3DCRT), forward-planned intensity-modulated radiotherapy (FP-IMRT), inverse-planned IMRT (IP-IMRT; 7- or 9-field), and hybrid IP-/FP-IMRT were compared in 10 patients. Clinical target volume (CTV) included CW and internal mammary (IM), supraclavicular (SC), and axillary nodes. Planning target volumes (PTVs), CTVs, and organs at risks (OARs) doses were analyzed with dose–volume histograms (DVHs). Results: No differences could be observed among the techniques for doses received by 95% of the volume (D95%) of lymphatics. However, the FP-IMRT resulted in a significantly lower D95% dose to the CW-PTV compared to other techniques (P = 0.002). The 9-field IP-IMRT achieved the lowest volumes receiving higher doses (hotspots). Both IP-IMRT techniques provided similar mean doses (Dmean) for the left lung which were smaller than the other techniques. There was no difference between the techniques for maximum dose (Dmax) of right breast. However, FP-IMRT resulted in lower Dmean and volume of right breast receiving at least 5 Gy doses compared to other techniques. Conclusion: The dose homogeneity in CW-CTV was better using IMRT techniques compared to 3DCRT. Especially 9-field IP-IMRT provided a more homogeneous dose distribution in IM and axillary CTVs. Moreover, the OARs volumes receiving low radiation doses were larger with IP-IMRT technique, while volumes receiving high radiation doses were larger with FP-IMRT technique. Hybrid IMRT plans were found to have the advantages of both FP- and IP-IMRT techniques.

Cite

CITATION STYLE

APA

Kivanc, H., Gultekin, M., Gurkaynak, M., Ozyigit, G., & Yildiz, F. (2019). Dosimetric comparison of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left-sided chest wall and lymphatic irradiation. Journal of Applied Clinical Medical Physics, 20(12), 36–44. https://doi.org/10.1002/acm2.12757

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free