Epicardial stenosis severity does not affect minimal microcirculatory resistance

233Citations
Citations of this article
105Readers
Mendeley users who have this article in their library.

Abstract

Background - Whether minimal microvascular resistance of the myocardium is affected by the presence of an epicardial stenosis is controversial. Recently, an index of microcirculatory resistance (IMR) was developed that is based on combined measurements of distal coronary pressure and thermodilution-derived mean transit time. In normal coronary arteries, IMR correlates well with true microvascular resistance. However, to be applicable in the case of an epicardial stenosis, IMR should account for collateral flow. We investigated the feasibility of determining IMR in humans and tested the hypothesis that microvascular resistance is independent of epicardial stenosis. Methods and Results - Thirty patients scheduled for percutaneous coronary intervention were studied. The stenosis was stented with a pressure guidewire, and coronary wedge pressure (Pw) was measured during balloon occlusion. After successful stenting, a short compliant balloon with a diameter 1.0 mm smaller than the stent was placed in the stented segment and inflated with increasing pressures, creating a 10%, 50%, and 75% area stenosis. At each of the 3 degrees of stenosis, fractional flow reserve (FFR) and IMR were measured at steady-state maximum hyperemia induced by intravenous adenosine. A total of 90 measurements were performed in 30 patients. When uncorrected for Pw, an apparent increase in microvascular resistance was observed with increasing stenosis severity (IMR=24, 27, and 37 U for the 3 different degrees of stenosis; P<0.001). In contrast, when Pw is appropriately accounted for, microvascular resistance did not change with stenosis severity (IMR=22, 23, and 23 U, respectively; P=0.28). Conclusions - Minimal microvascular resistance does not change with epicardial stenosis severity, and IMR is a specific index of microvascular resistance when collateral flow is properly taken into account.

Cite

CITATION STYLE

APA

Aarnoudse, W., Fearon, W. F., Manoharan, G., Geven, M., Van De Vosse, F., Rutten, M., … Pijls, N. H. J. (2004). Epicardial stenosis severity does not affect minimal microcirculatory resistance. Circulation, 110(15), 2137–2142. https://doi.org/10.1161/01.CIR.0000143893.18451.0E

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free