Abstract

Wearable cardioverter-defibrillators (WCDs) protect patients from sudden cardiac death (SCD) by detecting and treating life-threatening ventricular tachycardia/fibrillation (VT/VF). Recently, two large studies evaluating WCDs were published. However, the results of older and newer studies have yet to be systematically summarized. The objective of the current study was to conduct a meta-analysis assessing the use and effectiveness of WCDs. We searched MEDLINE and Scopus (January 1998-July 2017) as well as the gray literature. We included registry/observational studies that (1) evaluated adult patients using WCDs; (2) provided data on one or more outcomes of interest; and (3) were full-text studies published in English. We calculated pooled incidence and/or rate [with 95% confidence intervals (CIs)] estimates from nonoverlapping populations using a random-effects meta-analysis model. Statistical heterogeneity was assessed via the I2 statistic. We identified 11 studies (19,882 patients) with nonoverlapping populations/endpoints; seven of them evaluated WCD use across various indications, while the remaining studies restricted their focus to a single indication. Most of the studies were retrospective (82%) and multicenter (64%) in nature, with 45% using manufacturers' registry data. The median duration of WCD use was three or more months in nine (82%) studies, and daily wear time ranged from a mean/median of 17 hours to 24 hours per day across included studies. Seven (64%) studies reported a mean/median daily wear time of more than 20 hours. This meta-analysis showed that the incidences of all-cause and SCD-related mortality among WCD patients were 1.4% (95% CI: 0.7%-2.4%) and 0.2% (95% CI: 0.1%-0.3%), respectively. VT/VF occurred in 2.6% (95% CI: 1.8%-3.5%) of patients. Across patients, 1.7% (95% CI: 1.4%-2.0%) received appropriate WCD treatment, corresponding to a rate of 9.1 patients/100 person-years (95% CI: 6.2-11.9 patients/100 person-years). Successful VT/VF termination following appropriate treatment occurred in 95.5% of patients (95% CI: 92.0%-98.0%) and the incidence of inappropriate treatment was infrequent (0.9%; 95% CI: 0.5%-1.4%). A moderate-to-high degree of statistical heterogeneity was observed in pooled analyses of mortality, VT/VF occurrence, and appropriate/inappropriate treatment (I2 ≥ 41% for all). In conclusion, WCDs appear to be successful in terms of terminating VT/VF in patients with an elevated risk of SCD and are appropriate for use while long-term risk management strategies are being identified.

Cite

CITATION STYLE

APA

Nguyen, E., Weeda, E., Kohn, C., D’Souza, B., Russo, A., Noreika, S., & Coleman, C. (2018). Wearable Cardioverter-defibrillators for the Prevention of Sudden Cardiac Death: A Meta-analysis. The Journal of Innovations in Cardiac Rhythm Management, 9(5), 3151–3162. https://doi.org/10.19102/icrm.2018.090506

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free