Abstract
In order to determine a crack propagation rate of less than 10-8 mm/s in a 24-hour integrated measurement, major parameters of a coupled system of aconstant tension specimen and crack depth measurement, based on potential drop method, have been optimized. Influences of sensor geometry, location for detecting potential drop and data processing of the ratio of signal to noise (S/N) were optimized by applying Taguchi's Method.Then a suitable sensor geometry and data processing method were proposed to get a robust measurement system with higher sensitivity and lower susceptibility for geometrical and procedural fluctuations.By applying the optimal crack propagation rate measurement system, it was confirmed that a crack propagation rate of lxlO-8 mm/s can be measured under a low concentration condition of hydrogen peroxide with less than a 20% error by a 24-hour integrated measurement. © 2000 Taylor and Francis Group, LLC.
Author supplied keywords
Cite
CITATION STYLE
Uchida, S., Tachibana, M., Watanabe, A., Wada, Y., & Ishigure, K. (2000). Effects of Hydrogen Peroxide on Intergranular Stress Corrosion Cracking of Stainless Steel in High Temperature Water, (II). Journal of Nuclear Science and Technology, 37(3), 257–266. https://doi.org/10.1080/18811248.2000.9714892