Control system design of shunt active power filter based on active disturbance rejection and repetitive control techniques

12Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

To rely on joint active disturbance rejection control (ADRC) and repetitive control (RC), in this paper, a compound control law for active power filter (APF) current control system is proposed. According to the theory of ADRC, the uncertainties in the model and from the circumstance outside are considered as the unknown disturbance to the system. The extended state observer can evaluate the unknown disturbance. Next, RC is introduced into current loop to improve the steady characteristics. The ADRC is used to get a good dynamic performance, and RC is used to get a good static performance. A good simulation result is got through choosing and changing the parameters, and the feasibility, adaptability, and robustness of the control are testified by this result. © 2014 Le Ge et al.

Cite

CITATION STYLE

APA

Ge, L., Yuan, X., & Yang, Z. (2014). Control system design of shunt active power filter based on active disturbance rejection and repetitive control techniques. Mathematical Problems in Engineering, 2014. https://doi.org/10.1155/2014/864989