ANALISIS KADAR ASAM ASKORBAT (VITAMIN C ) PADA MINUMAN SUPLEMEN DALAM KEMASAN DENGAN METODE SPEKTROFOTOMETRI SECARA LANGSUNG DAN TIDAK LANGSUNG

  • Sudiarta I
  • Suandi I
  • Laksmiwati A
N/ACitations
Citations of this article
393Readers
Mendeley users who have this article in their library.

Abstract

Asam askorbat atau vitamin C banyak terdapat pada minuman suplemen kemasan yang mudah ditemukan dimanapun dan penggunaanya yang relatif lebih praktis. Untuk mengetahui kadar vitamin C yang tepat dalam minuman suplemen dilakukan pengukuran  dengan metode spektrofotometri UV-Vis secara langsung dan tidak langsung. Penelitian ini bertujuan untuk mengetahui metode manakah yang lebih baik untuk analisis vitamin C dan mengetahui apakah kadar vitamin C yang tercantum pada label minuman suplemen kemasan sesuai dengan hasil metode langsung dan tidak langsung. Sampel dipreparasi menggunakan metode spektrofotometri secara langsung dan tidak langsung menggunakan logam pereduksi Cr6+ yang direaksikan dengan vitamin C pada sampel dan dianalisis menggunakan spektrofotometer UV-Vis. Hasilnya menunjukkan bahwa analisis vitamin C dengan metode spektrofotometri lebih baik secara tidak langsung daripada secara langsung. Kadar vitamin C pada sampel minuman suplemen dalam kemasan A, B, dan C yang dianalisis dengan metode spektrofotometri secara langsung diperoleh masing-masing sebesar 1074,34 mg/L ; 5956,44 mg/L dan 6646,28 mg/L dengan nilai %kesesuaian kadar 88,91%, 89,35%, dan 89,66%. Sedangkan kadar vitamin C pada sampel minuman suplemen dalam kemasan A, B, dan C yang dianalisis dengan metode spektrofotometri secara tidak langsung diperoleh masing-masing 1178,17 mg/L ; 6162,41 mg/L dan 6718,58 mg/L dengan % kesesuaian kadar 97,50%, 92,44% dan 90,63%. Hasil uji -t menyatakan tidak ada perbedaan secara signifikan antara kadar vitamin C  sampel A yang dianalisis dengan metode tidak langsung dengan kadar yang tertera di label kemasan. Sedangkan kadar vitamin C pada sampel B tidak berbeda secara signifikan baik ditentukan dengan metode langsung maupun tidak langsung. Kata kunci: Cr6+, minuman suplemen dalam kemasan, spektrofotometer UV-Vis, Vitamin C. Ascorbic acid or vitamin C contained in many supplement drinks are easily found anywhere and its use is relatively more practical. To find out the exact content of vitamin C in supplement drinks, measurements were carried out directly and indirectly using UV-Vis spectrophotometry method. This study aims to find out which spectrophotometric method is better for vitamin C analysis and whether the vitamin C content listed on the supplement drink packaging label is in accordance with the results of the direct and indirect methods. Samples were prepared directly and indirectly using Cr6+ reducing metals reacted with the vitamin C in the samples and analyzed by using a UV-Vis spectrophotometer methods. The results showed that the analysis of vitamin C by indirect spectrophotometric method was better than the direct one. Vitamin C contents in the supplement beverage samples of packaging A, B, and C analyzed using direct spectrophotometric method were 1074.34 mg/L; 5956.44 mg/L and 6646.28 mg/L with percentage of conformity of 88% 91.91%, 89.35% and 89.66%, respectively. Meanwhile, the vitamin C contents in the supplement drink samples of packaging A, B, and C analyzed by indirect spectrophotometric method were 1178.17 mg/L; 6162.41 mg/L and 6718.58 mg/L with percentage of conformity of 97.50%, 92.44% and 90.63%. The -t test results indicated that there was no significant difference of vitamin C content in the sample A analyzed by indirect methods from the content listed on the packaging label. The -t test results also stated that there is no significant difference of vitamin C content in the sample B analyzed either by direct or indirect method. Keywords: bottled supplement drinks, Cr6+, UV-Vis Spectrophotometer, vitamin C.

Cite

CITATION STYLE

APA

Sudiarta, I. W., Suandi, I. P. G. A., & Laksmiwati, A. A. I. A. M. (2021). ANALISIS KADAR ASAM ASKORBAT (VITAMIN C ) PADA MINUMAN SUPLEMEN DALAM KEMASAN DENGAN METODE SPEKTROFOTOMETRI SECARA LANGSUNG DAN TIDAK LANGSUNG. Jurnal Kimia, 140. https://doi.org/10.24843/jchem.2021.v15.i02.p03

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free