Immunomagnetic flow cytometric detection of staphylococcal enterotoxin B in raw and dry milk

23Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A rapid and sensitive method for detection of staphylococcal enterotoxin B (SEB) in raw and dry milk samples with the use of antibody-based immunomagnetic separation (IMS) in conjunction with flow cytometry (FCM) was developed. Sheep anti-SEB immunoglobulin G (IgG) was immobilized on Dynabeads M-280. The SEB initially binds to the capturing antibody, which is bound on the magnetic beads. The rabbit anti-SEB IgG binds to the captured toxin and is further labeled with a Cy5-labeled goat anti-rabbit IgG antibody. The percentage of the beads that were fluorescent was measured by FCM. FCM was carried out for 1 min, and the data obtained were expressed as histograms for particle size (forward light scatter) and histograms for fluorescence intensity. A peak corresponding to the magnetic beads was clearly distinguished from a peak derived from contaminating particles in the sample solution. In the absence of SEB, about 10% of the beads emitted fluorescence. The percentage of fluorescent beads and the fluorescence intensity increased with increasing SEB concentrations. For this IMS-FCM assay, the lower limits of detection for SEB were estimated to be 0.01 and 0.25 ng/ml for buffer and milk samples, respectively.

Cite

CITATION STYLE

APA

Miyamoto, T., Kamikado, H., Kobayashi, H., Honjoh, K. I., & Iio, M. (2003). Immunomagnetic flow cytometric detection of staphylococcal enterotoxin B in raw and dry milk. Journal of Food Protection, 66(7), 1222–1226. https://doi.org/10.4315/0362-028X-66.7.1222

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free