Home monitoring of transcutaneous oxygen tension in the early detection of hypoxaemia in infants and young children

37Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

Twenty three patients (age range 0.5-40 months) with recurrent cyanotic episodes underwent physiological recordings, including transcutaneous oxygen tension (TcPO2) from a monitor modified for use at home (Kontron 821S). Of 69 episodes in which the arterial oxygen saturation (SaO2, Nellcor N200) was ≤80% for ≥20 seconds and/or central cyanosis was present, the TcPO2 monitor alarmed (≤20 mmHg or 2.67 kPa) in every episode. The pulse oximeter identified hypoxaemia in 62 out of 69 episodes, failing in seven episodes due to signal loss from movement artefact. In only seven of 69 episodes was there an accompanying apnoeic pause (≥20 seconds), and heart rate fell to ≤80 beats/minute in only five of 28 episodes in which an electrocardiogram was recorded. In 32 episodes in which SaO2 fell to ≤60%, the TcPO2 monitor alarmed after a median time interal of 16 seconds (maximum time interval 30 seconds). The TcPO2 monitor was then used in an uncontrolled trial at home in 350 patients at increased risk of sudden death and/or hypoxaemia. Indications for monitoring included apparent life threatening events or cyanotic episodes (n=163), prematurity and prematurity related disorders (n=86), and sudden unexpected death in one or more siblings (n=122). The TcPO2 monitor detected cyanotic episodes at home in 81 patients, 52 of whom received vigorous stimulation and/or mouth to mouth resuscitation. Twenty one of these 52 patients had further hypoxaemic episodes documented in hospital with pulse oximetry. In 30 patients, the TcPO2 monitor also identified the gradual development of hypoxaemia, as confirmed by pulse oximetry. Twenty of these needed additional inspired oxygen and six subsequently needed ventilatory support in hospital. This TcPO2 monitor is a reliable detector of both sudden and gradual onset hypoxaemia and is able to be used by parents in the home.

Cite

CITATION STYLE

APA

Poets, C. F., Samuels, M. P., Noyes, J. P., Jones, K. A., & Southall, D. P. (1991). Home monitoring of transcutaneous oxygen tension in the early detection of hypoxaemia in infants and young children. Archives of Disease in Childhood, 66(6), 676–682. https://doi.org/10.1136/adc.66.6.676

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free