Size matters: Spleen and lung volumes predict performance in human apneic divers

81Citations
Citations of this article
124Readers
Mendeley users who have this article in their library.

Abstract

Humans share with seals the ability to contract the spleen and increase circulating hemat-ocrit, which may improve apneic performance by enhancing gas storage. Seals have large spleens and while human spleen size is small in comparison, it shows great individual variation. Unlike many marine mammals, human divers rely to a great extent on lung oxygen stores, but the impact of lung volume on competitive apnea performance has never been determined. We studied if spleen- and lung size correlated with performance in elite apnea divers. Volunteers were 14 male apnea world championship participants, with a mean (SE) of 5.8 (1.2)years of previous apnea training. Spleen volume was calculated from spleen length, width, and thickness measured via ultrasound during rest, and vital capacity via spirometry. Accumulated competition scores from dives of maximal depth, time, and distance were compared to anthropometric measurements and training data. Mean (SE) diving performance was 75 (4) m for constant weight depth, 5 min 53 (39) s for static apnea and 139 (13) m for dynamic apnea distance. Subjects' mean height was 184 (2) cm, weight 82 (3) kg, vital capacity (VC) 7.3 (0.3) L and spleen volume 336 (32) mL. Spleen volume did not correlate with subject height or weight, but was positively correlated with competition score (r = 0.57; P< 0.05). Total competition score was also positively correlated with VC (r = 0.54; P<0.05). The three highest scoring divers had the greatest spleen volumes, averaging 538 (53) mL, while the three lowest-scoring divers had a volume of 270 (71) mL (P < 0.01). VC was also greater in the high-scorers, at 7.9 (0.36) L as compared to 6.7 (0.19) L in the low scorers (P<0.01). Spleen volume was reduced to half after 2 min of apnea in the highest scoring divers, and the estimated resting apnea time gain from the difference between high and low scorers was 15s for spleen volume and 60s forVC. We conclude that both spleen- and lung volume predict apnea performance in elite divers. © 2012 Schagatay, Richardson and Lodin-Sundström.

Cite

CITATION STYLE

APA

Schagatay, E., Richardson, M. X., & Lodin-Sundström, A. (2012). Size matters: Spleen and lung volumes predict performance in human apneic divers. Frontiers in Physiology, 3 JUN. https://doi.org/10.3389/fphys.2012.00173

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free