Background: To investigate repair of iris defects by endocapsular implantation of an artificial iris, in relation to visual outcomes, safety profile and patient satisfaction. Methods: Retrospective, consecutive case series from Greenlane tertiary teaching hospital and Eye Institute, Auckland, New Zealand. Medical records of patients implanted with an endocapsular artificial iris were reviewed and followed for minimum 3 months. Patient characteristics, surgical management, clinical outcomes and subjective responses were recorded. Results: Nineteen artificial irises were implanted in 18 patients. Etiologies were iris melanotic lesion excision (73.7%), trauma (10.5%), congenital aniridia (10.5%) and Urrets-Zavalia syndrome (5.3%). During postoperative follow-up [14.1 ± 12.4 months (range: 3 to 59 months)], best corrected visual acuity (BCVA) and intraocular pressure (IOP) did not change significantly [BCVA, 0.23 logarithm of the minimum angle of resolution (logMAR) (20/32 Snellen) preoperatively vs. 0.18 logMAR postoperatively (20/25 Snellen) (Z = −0.222, p = 0.824); IOP, 15 mmHg preoperatively vs. 17 mmHg postoperatively (Z = 1.377, p = 0.1447)]. Mild or self-limiting complications included: elevated IOP (42.1%), cystoid macular oedema (15.8%); persisting postoperative uveitis (15.8%) and minor vaulting of the prosthesis (15.7%). Moderate or severe complications included significant vaulting of prosthesis requiring surgical revision (5.3%) and a single eye (5.3%) with trabeculectomy and corneal graft failure. 94.4% of patients were very satisfied with the cosmesis and would be highly likely to have the procedure again. Conclusions: This study confirms that endocapsular insertion of an artificial iris is typically associated with good functional and cosmetic results and a relatively low risk of significant complications.

Cite

CITATION STYLE

APA

Crawford, A. Z., Freundlich, S. E. N., Lim, J., & McGhee, C. N. J. (2022). Endocapsular artificial iris implantation for iris defects: Reducing symptoms, restoring visual function and improving cosmesis. Clinical and Experimental Ophthalmology, 50(5), 490–499. https://doi.org/10.1111/ceo.14083

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free