Early and late results of partial plication annuloplasty for congenital mitral insufficiency

12Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Partial plication annuloplasty is the main technique for congenital mitral insufficiency because this technique allows the mitral anulus to grow, in contrast to ring annuloplasty. However, this technique is not satisfactory for mitral insufficiency with some anomalies of the mitral valve apparatus. Methods: Forty-one patients underwent partial plication annuloplasty for mitral regurgitation from July 1979 to December 1998. Mitral regurgitation associated with an atrioventricular defect, an atrioventricular discordance, and a univentricular heart was excluded from this study. Results: There were no early or late deaths. In early results, partial plication annuloplasty was more effective for mitral regurgitation with abnormality of the posterior leaflet (n = 14) or normal leaflet motion (n = 8) than with abnormality of the anterior leaflet and its apparatus (n = 14) or absence of chordae (n = 4). The mean follow-up period was 145.8 months. During the follow-up period, 2 patients underwent mitral valve replacement, and a third patient underwent mitral valve repair with partial plication annuloplasty after the first repair. The main cause of mitral regurgitation of 2 of the 3 patients was absence of chordae. The actuarial freedom from reoperation rate was 94.9% ± 3.6%, 91.9% ± 4.7%, and 91.9% ± 4.7% at 5, 10, and 15 years after the operation, respectively. Conclusion: Early and long-term results of partial plication annuloplasty were acceptable for congenital mitral insufficiency with any type of malformation of the mitral valve, and results were excellent with abnormality of the posterior leaflet and its apparatus or normal leaflet motion. However, late results were suboptimal for mitral regurgitation with absence of chordae. Other techniques, such as artificial chorda replacement, should be adapted in these cases.

Cite

CITATION STYLE

APA

Sugita, T., Ueda, Y., Matsumoto, M., Ogino, H., Nishizawa, J. ichiro, & Matsuyama, K. (2001). Early and late results of partial plication annuloplasty for congenital mitral insufficiency. Journal of Thoracic and Cardiovascular Surgery, 122(2), 229–233. https://doi.org/10.1067/mtc.2001.115157

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free