Biomechanical evaluation comparing zero-profile devices versus fixed profile systems in a cervical hybrid decompression model: a biomechanical in vitro study

7Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.
Get full text

Abstract

BACKGROUND CONTEXT: The use of zero-profile devices and the need for posterior fixation in conjunction with a cervical hybrid decompression model have yet to be investigated. PURPOSE: To compare the biomechanics of zero-profile and fixed profile cervical hybrid constructs composed of anterior cervical discectomy and fusion (ACDF) and anterior cervical corpectomy and fusion (ACCF). Fixed profile devices included anterior plating, whereas zero-profile devices included integrated screws. STUDY DESIGN: In vitro cadaveric biomechanical study. METHODS: Twelve fresh-frozen cadaveric spines (C2–C7) were divided into two groups of equal bone mineral density, fixed profile versus zero profile (n=6). Groups were instrumented from C3–C6 with either (1) an expandable ACCF device and a static ACDF spacer with an anterior plate (Hybrid-AP) or (2) a zero-profile ACCF spacer with adjacent zero-profile ACDF spacer (Hybrid-Z). Motion was captured for the (1) intact condition, (2) a hybrid model with lateral mass screws (LMS), (3) a hybrid model without LMS, and (4) a hybrid model without LMS following simulated repetitive loading (fatigue). RESULTS: Hybrid-AP with LMS reduced motion in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) by 77%, 88%, and 82%, respectively, compared with intact. Likewise, Hybrid-Z with LMS exhibited the greatest reduction in motion relative to intact in FE, LB, and AR by 90%, 95%, and 66%, respectively. Following simulated in vivo fatiguing, an increase in motion was observed for both groups in all planes, particularly during Hybrid-Z postfatigue condition where motion increased relative to intact by 29%. Overall, biomechanical equivalency was observed between Hybrid-AP and Hybrid-Z groups (p>.05). Three (50%) of the Hybrid-Z group specimens exhibited signs of implant migration from the inferior endplate during testing. CONCLUSIONS: Fixed profile systems using an anterior plate for supplemental fixation is biomechanically more favorable to maintain stability and prevent dislodgement. Dislodgement of 50% of the Hybrid-Z group without LMS emphasizes the necessity for posterior fixation in a zero-profile cervical hybrid decompression model.

Cite

CITATION STYLE

APA

Kinon, M. D., Greeley, S. L., Harris, J. A., Gelfand, Y., Yassari, R., Nakhla, J., … Bucklen, B. S. (2020). Biomechanical evaluation comparing zero-profile devices versus fixed profile systems in a cervical hybrid decompression model: a biomechanical in vitro study. Spine Journal, 20(4), 657–664. https://doi.org/10.1016/j.spinee.2019.10.004

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free