Diagnostic Performance of Indocyanine Green Plus Methylene Blue Versus Radioisotope Plus Methylene Blue Dye Method for Sentinel Lymph Node Biopsy in Node-Negative Early Breast Cancer

  • Agrawal S
  • Hashlamoun I
  • Karki B
  • et al.
24Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

Abstract

PURPOSE Sentinel lymph node biopsy (SLNB) by dual-dye method (radioisotope plus blue) is the gold standard for axillary staging in patients with breast cancer, but in developing countries, logistic issues and financial constraint play a vital role. Recently, indocyanine green (ICG) has emerged as an alternative to radioisotope (technetium-99 [Tc-99]) for SLNB in breast cancer. This study compared the diagnostic performance of Tc-99 plus methylene blue (MB) dye versus ICG + MB dye SLNB. METHODS Two hundred seven patients with early breast cancer (T1-3N0) were included in the study from 2017 to 2019. SLNB was done either with Tc-99 + MB or with ICG + MB as per availability of radioisotope. SLN identification rate (IR), SLN positivity rate, and metastatic SLN counts were compared between the 2 groups. RESULTS IR was 199 (96%) of 207. IR was 95% in Tc-99 + MB compared with 97% with ICG + MB. The mean number of SLNs identified were 3.17 (standard deviation [SD], 1.84), with. 1 SLN identified in 87% patients by Tc-99 + MB. SLN was positive in 31.3% of patients with a metastatic SLN count of 0.37 (SD, 0.76). With ICG + MB, the number of SLNs was 2.73 (SD, 1.55), with. 1 SLN identified in 79% of patients. Twenty-eight percent of patients had positive SLNs, with a metastatic SLN count of 0.41 (SD, 0.77). A sharp decline in the availability of Tc-99 was observed, with 58% of patients in 2014 and only 12% of patients in 2018. CONCLUSION ICG is equivalent to Tc-99 for SLNB in early breast cancer and has a good potential to be adopted by surgeons in resource-constrained setups.

Cite

CITATION STYLE

APA

Agrawal, S. K., Hashlamoun, I., Karki, B., Sharma, A., Arun, I., & Ahmed, R. (2020). Diagnostic Performance of Indocyanine Green Plus Methylene Blue Versus Radioisotope Plus Methylene Blue Dye Method for Sentinel Lymph Node Biopsy in Node-Negative Early Breast Cancer. JCO Global Oncology, (6), 1225–1231. https://doi.org/10.1200/go.20.00165

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free