Airborne Transmission Risk in Urban Buses: A Computational Fluid Dynamics Study

17Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The Heat, Ventilation, Air Conditioning (HVAC) systems in urban buses promote high particle motion. In this paper the effect of centralized roof-top HVAC on virus transmission by droplets caused by sneezing and coughing was studied with the Lagrangian approach while the transmission through aerosols caused by breathing and talking was modeled with the Eulerian tracer method. It was found that the large droplets (> 200 µm) can travel more than 3 m without being affected by the airflow. On the other hand, the small droplets (< 5 µm) are easily dragged, dispersed, and also captured by the HVAC. On the other hand, aerosols are quickly spread by the HVAC. It was found that the centralized roof-top HVAC reduces the concentration in the central zone, but it is ineffective to renew the air in the front and rear sides. The Wells-Riley risk model showed that the average risk across the whole bus can be reduced to a half and a quarter by renewing the air of the cabin 10 times per hour.

Cite

CITATION STYLE

APA

Ramajo, D. E., & Corzo, S. (2022). Airborne Transmission Risk in Urban Buses: A Computational Fluid Dynamics Study. Aerosol and Air Quality Research, 22(8). https://doi.org/10.4209/aaqr.210334

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley